需申請審核

Head-and-neck squamous cell carcinoma patients with 3D CT taken during pre-treatment, mid-treatment, and post-treatment (HNSCC-3DCT-RT)

Researchers will have the unique opportunity to visualize how head-and-neck squamous cell carcinoma (HNSCC) patients’ 3D CT image data changes with radiotherapy between pre-treatment, mid-treatment, and post-treatment. They will also have the advantage to receive additional information such as a) photon energy, b) number of arcs for volumetric modulated arc radiotherapy (VMAT) therapy, c) tumor volume and location, d) CT-to-density table, e) treatment related toxicities for parotid glands and oral cavity, f) patient age and weight, patient chemotherapy medication, g) prior surgery, h) performance status, i) histology, j) disease stage, k) number of targets, l) organs at risk, and m) other structures delineated on the CT image. This data collection contains three dimensional high-resolution (3D) fan-beam CT scans collected during pre-treatment, mid-treatment, and post-treatment using a Siemens 16-slice CT scanner with standard clinical protocol for 31 head-and-neck squamous cell carcinoma (HNSCC) patients. Patients underwent radiotherapy treatment to a total dose of 58-70 Gy, using daily 2-2.20 Gy, fractions for 30-35 fractions. The pre-treatment planning CT scans were performed with a median of 13 days (range: 2-27) before treatment, the mid-treatment CT was performed at fraction 17 (range: 8-26), and the post-treatment CT around fraction 30 (range: 26th fraction - 21 weeks post treatment). In addition to the imaging data, the data sets contain contours of anatomical structures for radiotherapy. The contours were generated by the attending radiation oncologists for treatment planning purposes, and subsequently treatment plans were generated with Eclipse® (Varian Medical Systems, Inc., Palo Alto, CA) treatment planning system. In addition to CT image data, included are: a) photon energy, b) number of arcs for volumetric modulated arc radiotherapy (VMAT) therapy, c) tumor volume and location, d) CT-to-density table, e) treatment related toxicities for parotid glands and oral cavity, f) patient age and weight, patient chemotherapy medication, g) prior surgery, h) performance status, i) histology, j) disease stage, k) number of targets, l) organs at risk, and m) other structures delineated on the CT image.

All patients were recruited according to the following criteria. Inclusion: i) patients had histologically confirmed head-and-neck tumors, ii) were treated with definitive radiation therapy or concurrent chemoradiation therapy, iii) patients treated with post-operative radiation therapy, for whom the gross tumor volume (GTV) or the resection cavity were visible on CT, such that it could be delineated as a target for radiotherapy, iv) patients were informed of the investigational nature of this study and were able to understand and to sign a written informed consent document.

Exclusion: i) pregnant or nursing women were not eligible to participate, ii) women of reproductive potential must have been offered a pre-treatment pregnancy test and informed of the need to practice an effective contraceptive method, iii) patients younger than 18 years, and iv) patients whose size and weight would not allow CT scanning.

資料與資源

額外的資訊

欄位
最後更新 十二月 3, 2019, 14:14 (CST)
建立 十月 16, 2018, 08:40 (CST)

推薦資料集:


  • 110年4月花蓮縣使用牌照稅稽徵

    付費方式 免費
    更新頻率 不定期
    110年花蓮縣使用牌照稅稽徵
  • 台灣中油股份有限公司_中油生技經銷商名單

    付費方式 免費
    更新頻率 不定期
    生技經銷商名單收集的目的是為消費者知道那裡可購買生技產品也透過經銷商拓展生技業務;本事業部生技經銷商是透過公開甄選,並經行銷部門審核後才能販售本事業部生技產品。(本年度生技產品現在由本公司加油站銷售,服務專線為1912,目前暫無外部經銷商名單,若有最新經銷商名單,再行更新。)
  • 財政部南區國稅局國稅統計年報

    付費方式 免費
    更新頻率 不定期
    南區國稅局年度國稅統計年報資料
  • 臺南市政府消防局各單位地址名冊

    付費方式 免費
    更新頻率 不定期
    本資料集提供臺南市政府消防局各單位地址名冊資訊。
  • 新北市老人健康檢查醫療院所-萬里區

    付費方式 免費
    更新頻率 不定期
    新北市老人健康檢查醫療院所-萬里區