Applicaiton Required

Head-and-neck squamous cell carcinoma patients with 3D CT taken during pre-treatment, mid-treatment, and post-treatment (HNSCC-3DCT-RT)

Researchers will have the unique opportunity to visualize how head-and-neck squamous cell carcinoma (HNSCC) patients’ 3D CT image data changes with radiotherapy between pre-treatment, mid-treatment, and post-treatment. They will also have the advantage to receive additional information such as a) photon energy, b) number of arcs for volumetric modulated arc radiotherapy (VMAT) therapy, c) tumor volume and location, d) CT-to-density table, e) treatment related toxicities for parotid glands and oral cavity, f) patient age and weight, patient chemotherapy medication, g) prior surgery, h) performance status, i) histology, j) disease stage, k) number of targets, l) organs at risk, and m) other structures delineated on the CT image. This data collection contains three dimensional high-resolution (3D) fan-beam CT scans collected during pre-treatment, mid-treatment, and post-treatment using a Siemens 16-slice CT scanner with standard clinical protocol for 31 head-and-neck squamous cell carcinoma (HNSCC) patients. Patients underwent radiotherapy treatment to a total dose of 58-70 Gy, using daily 2-2.20 Gy, fractions for 30-35 fractions. The pre-treatment planning CT scans were performed with a median of 13 days (range: 2-27) before treatment, the mid-treatment CT was performed at fraction 17 (range: 8-26), and the post-treatment CT around fraction 30 (range: 26th fraction - 21 weeks post treatment). In addition to the imaging data, the data sets contain contours of anatomical structures for radiotherapy. The contours were generated by the attending radiation oncologists for treatment planning purposes, and subsequently treatment plans were generated with Eclipse® (Varian Medical Systems, Inc., Palo Alto, CA) treatment planning system. In addition to CT image data, included are: a) photon energy, b) number of arcs for volumetric modulated arc radiotherapy (VMAT) therapy, c) tumor volume and location, d) CT-to-density table, e) treatment related toxicities for parotid glands and oral cavity, f) patient age and weight, patient chemotherapy medication, g) prior surgery, h) performance status, i) histology, j) disease stage, k) number of targets, l) organs at risk, and m) other structures delineated on the CT image.

All patients were recruited according to the following criteria. Inclusion: i) patients had histologically confirmed head-and-neck tumors, ii) were treated with definitive radiation therapy or concurrent chemoradiation therapy, iii) patients treated with post-operative radiation therapy, for whom the gross tumor volume (GTV) or the resection cavity were visible on CT, such that it could be delineated as a target for radiotherapy, iv) patients were informed of the investigational nature of this study and were able to understand and to sign a written informed consent document.

Exclusion: i) pregnant or nursing women were not eligible to participate, ii) women of reproductive potential must have been offered a pre-treatment pregnancy test and informed of the need to practice an effective contraceptive method, iii) patients younger than 18 years, and iv) patients whose size and weight would not allow CT scanning.

データとリソース

追加情報

フィールド 値
最終更新 12月 3, 2019, 14:14 (CST)
作成日 10月 16, 2018, 08:40 (CST)

推薦資料集:


  • insight_test_11900

    Payment instrument Free
    Update frequency Irregular
  • 新北市公司登記資料-B礦業及土石採取業

    Payment instrument Free
    Update frequency Irregular
    提供新北市公司營業項目為B礦業及土石採取業之登記資料及營業地址。
  • Applicaiton Required

    2025年福爾摩沙衛星五號 L1A 屏東

    Payment instrument Free
    Update frequency Irregular
    此資料集為非公開資料,需由 TASA 進行資料審核。 欲申請者,請進入資料集後點選右上方「申請」填寫申請單;申請前請先登入系統。 若尚無平台帳號,請至 https://scidm.nchc.org.tw/user/register 進行註冊
  • 新北市成人預防保健醫事機構--------------

    Payment instrument Free
    Update frequency Irregular
    新北市成人預防保健醫事機構清冊--------------
  • 臺中市居家護理所名冊

    Payment instrument Free
    Update frequency Irregular
    臺中市居家護理所名冊