沒有權限瀏覽此頁面
Applicaiton Required

Head-and-neck squamous cell carcinoma patients with 3D CT taken during pre-treatment, mid-treatment, and post-treatment (HNSCC-3DCT-RT)

Researchers will have the unique opportunity to visualize how head-and-neck squamous cell carcinoma (HNSCC) patients’ 3D CT image data changes with radiotherapy between pre-treatment, mid-treatment, and post-treatment. They will also have the advantage to receive additional information such as a) photon energy, b) number of arcs for volumetric modulated arc radiotherapy (VMAT) therapy, c) tumor volume and location, d) CT-to-density table, e) treatment related toxicities for parotid glands and oral cavity, f) patient age and weight, patient chemotherapy medication, g) prior surgery, h) performance status, i) histology, j) disease stage, k) number of targets, l) organs at risk, and m) other structures delineated on the CT image. This data collection contains three dimensional high-resolution (3D) fan-beam CT scans collected during pre-treatment, mid-treatment, and post-treatment using a Siemens 16-slice CT scanner with standard clinical protocol for 31 head-and-neck squamous cell carcinoma (HNSCC) patients. Patients underwent radiotherapy treatment to a total dose of 58-70 Gy, using daily 2-2.20 Gy, fractions for 30-35 fractions. The pre-treatment planning CT scans were performed with a median of 13 days (range: 2-27) before treatment, the mid-treatment CT was performed at fraction 17 (range: 8-26), and the post-treatment CT around fraction 30 (range: 26th fraction - 21 weeks post treatment). In addition to the imaging data, the data sets contain contours of anatomical structures for radiotherapy. The contours were generated by the attending radiation oncologists for treatment planning purposes, and subsequently treatment plans were generated with Eclipse® (Varian Medical Systems, Inc., Palo Alto, CA) treatment planning system. In addition to CT image data, included are: a) photon energy, b) number of arcs for volumetric modulated arc radiotherapy (VMAT) therapy, c) tumor volume and location, d) CT-to-density table, e) treatment related toxicities for parotid glands and oral cavity, f) patient age and weight, patient chemotherapy medication, g) prior surgery, h) performance status, i) histology, j) disease stage, k) number of targets, l) organs at risk, and m) other structures delineated on the CT image.

All patients were recruited according to the following criteria. Inclusion: i) patients had histologically confirmed head-and-neck tumors, ii) were treated with definitive radiation therapy or concurrent chemoradiation therapy, iii) patients treated with post-operative radiation therapy, for whom the gross tumor volume (GTV) or the resection cavity were visible on CT, such that it could be delineated as a target for radiotherapy, iv) patients were informed of the investigational nature of this study and were able to understand and to sign a written informed consent document.

Exclusion: i) pregnant or nursing women were not eligible to participate, ii) women of reproductive potential must have been offered a pre-treatment pregnancy test and informed of the need to practice an effective contraceptive method, iii) patients younger than 18 years, and iv) patients whose size and weight would not allow CT scanning.

Data and Resources

Additional Info

Field Value
Last Updated December 3, 2019, 14:14 (CST)
Created October 16, 2018, 08:40 (CST)

推薦資料集:


  • 臺南市政府核發建築物建造執照構造別統計

    Payment instrument Free
    Update frequency Irregular
    提供臺南市政府核發建築物建造執照構造別統計資料
  • 海關單一窗口聯絡人

    Payment instrument Free
    Update frequency Irregular
    提供海關單一窗口聯絡人
  • 輸入錠狀膠囊狀食品查驗登記資料集

    Payment instrument Free
    Update frequency Irregular
    藉由本資料集可查詢經衛生福利部查驗登記核備之輸入膠囊錠狀食品相關資訊。
  • 順向坡分布航照判釋

    Payment instrument Free
    Update frequency Irregular
    臺灣順向坡分布航照判釋WMS
  • 新北市里長資訊-樹林區

    Payment instrument Free
    Update frequency Irregular
    新北市全市1032里里長聯絡資訊-樹林區