The RIDER Lung CT collection was constructed as part of a study to evaluate the variability of tumor unidimensional, bidimensional, and volumetric measurements on same-day repeat computed tomographic (CT) scans in patients with non–small cell lung cancer. Thirty-two patients with non–small cell lung cancer, each of whom underwent two CT scans of the chest within 15 minutes by using the same imaging protocol, were included in this study. Three radiologists independently measured the two greatest diameters of each lesion on both scans and, during another session, measured the same tumors on the first scan. In a separate analysis, computer software was applied to assist in the calculation of the two greatest diameters and the volume of each lesion on both scans. Concordance correlation coefficients (CCCs) and Bland-Altman plots were used to assess the agreements between the measurements of the two repeat scans (reproducibility) and between the two repeat readings of the same scan (repeatability).

The reproducibility and repeatability of the three radiologists' measurements were high (all CCCs, ≥0.96). The reproducibility of the computer-aided measurements was even higher (all CCCs, 1.00). The 95% limits of agreements for the computer-aided unidimensional, bidimensional, and volumetric measurements on two repeat scans were (−7.3%, 6.2%), (−17.6%, 19.8%), and (−12.1%, 13.4%), respectively. Chest CT scans are well reproducible. Changes in unidimensional lesion size of 8% or greater exceed the measurement variability of the computer method and can be considered significant when estimating the outcome of therapy in a patient.

データとリソース

追加情報

フィールド
最終更新 12月 3, 2019, 13:21 (CST)
作成日 10月 15, 2018, 20:52 (CST)

推薦資料集:


  • 110年5月臺南市不動產實價登錄資訊(買賣案件)

    Payment instrument Free
    Update frequency Irregular
    提供110年5月臺南市不動產實價登錄資訊(買賣案件)
  • 107年公告地價及公告現值-蘆竹區

    Payment instrument Free
    Update frequency Irregular
    提供蘆竹區107年公告地價及公告現值
  • 臺北市公立幼兒園通訊資料

    Payment instrument Free
    Update frequency Irregular
    臺北市各行政區公立幼兒園名稱、電話及地址
  • Applicaiton Required

    CBIS-DDSM

    Payment instrument Free
    Update frequency Irregular
    Breast Cancer This CBIS-DDSM (Curated Breast Imaging Subset of DDSM) is an updated and standardized version of the Digital Database for Screening Mammography (DDSM). The DDSM...
  • 研發替代役各梯次分發需用機關人數─按梯次別、機關別分

    Payment instrument Free
    Update frequency Irregular
    研發替代役各梯次分發需用機關人數─按梯次別、機關別分(資料起始時間:97年)