Applicaiton Required

4D-Lung

This data collection consists of images acquired during chemoradiotherapy of 20 locally-advanced, non-small cell lung cancer patients. The images include four-dimensional (4D) fan beam (4D-FBCT) and 4D cone beam CT (4D-CBCT). All patients underwent concurrent radiochemotherapy to a total dose of 64.8-70 Gy using daily 1.8 or 2 Gy fractions. 4D-FBCT images were acquired on a 16-slice helical CT scanner (Brilliance Big Bore, Philips Medical Systems, Andover, MA) as respiration-correlated CTs with 10 breathing phases (0 to 90%, phase-based binning) and 3 mm slice thickness. 4D-FBCT images were acquired during simulation, prior to therapy, and used for therapy planning. In 14 of the 20 subjects, 4D-FBCTs were also acquired on the same scanner weekly during therapy. 4D-CBCT images were acquired on a commercial CBCT scanner (On-Board Imager™, Varian Medical Systems, Inc.). An external surrogate (Real-time Position Management, Varian Medical Systems, Inc.) was integrated into the CBCT acquisition system to stamp each CBCT projection with the surrogate respiratory signal through in-house software and hardware tools. Approximately 2500 projections were acquired over a period of 8-10 minutes in half-fan mode with half bow-tie filter. The technique was 125 kVp, 20 mA, and 20 ms in a single 360° slow gantry arc. Using the external surrogate, the CBCT projections were sorted into 10 breathing phases (0 to 90%, phase-based binning) and reconstructed with an in-house FDK reconstruction algorithm.

Audio-visual biofeedback was performed for all 4D-FBCT and 4D-CBCT acquisitions in all subjects. A single Radiation Oncologist delineated targets and organs at risk in all 4D-FBCT and a limited number of 4D-CBCT images, on all 10 phases per scan. Seven of the subjects had gold coils implanted as fiducial markers in or near the tumor.

For questions and information regarding this dataset, please contact Geoff Hugo, gdhugo@wustl.edu.

Data collection and analysis was supported by NIH P01CA116602.

データとリソース

このデータセットにはデータがありません

追加情報

フィールド
最終更新 12月 3, 2019, 14:29 (CST)
作成日 2月 14, 2019, 10:19 (CST)

推薦資料集:


  • 不動產實價登錄資訊-買賣案件-永和區

    Payment instrument Free
    Update frequency Irregular
    不動產買賣案件實價登錄資訊,包含標的位置、面積、總價等資訊。2. 本資料集為每10日更新一次。-永和區
  • 109年4月臺南市登革熱誘卵桶監測資訊

    Payment instrument Free
    Update frequency Irregular
    109年4月-臺南市登革熱誘卵桶監測資訊
  • Applicaiton Required

    NSTC 105-2634-F-244-001

    Payment instrument Free
    Update frequency Irregular
    科技部 巨量資料產學共創 - 資料管理規劃 巨量資料分析結合逆向工程於複合式風渦輪機葉片咖傳動機構設計並電能轉換優化之研製 2001年-2015年風紋資料 2001年-2015年旗津地區風紋資料
  • 106年度行政院農業委員會特有生物研究保育中心會計報告

    Payment instrument Free
    Update frequency Irregular
    提供106年度行政院農業委員會特有生物研究保育中心會計報告下載網址。
  • 109年第2季花蓮縣印花稅徵收-2

    Payment instrument Free
    Update frequency Irregular
    109年第2季花蓮縣印花稅徵收